forked from luck/tmp_suning_uos_patched
PCI/AER: Add bus flag to skip source ID matching
Allow root port buses to choose to skip source id matching when finding the faulting device. Certain root port devices may return an incorrect source ID and recommend to scan child device registers for AER notifications. Signed-off-by: Jon Derrick <jonathan.derrick@intel.com> Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
This commit is contained in:
parent
29b4817d40
commit
032c3d86b4
@ -132,7 +132,9 @@ static bool is_error_source(struct pci_dev *dev, struct aer_err_info *e_info)
|
||||
* When bus id is equal to 0, it might be a bad id
|
||||
* reported by root port.
|
||||
*/
|
||||
if (!nosourceid && (PCI_BUS_NUM(e_info->id) != 0)) {
|
||||
if (!nosourceid &&
|
||||
(PCI_BUS_NUM(e_info->id) != 0) &&
|
||||
!(dev->bus->bus_flags & PCI_BUS_FLAGS_NO_AERSID)) {
|
||||
/* Device ID match? */
|
||||
if (e_info->id == ((dev->bus->number << 8) | dev->devfn))
|
||||
return true;
|
||||
@ -147,7 +149,8 @@ static bool is_error_source(struct pci_dev *dev, struct aer_err_info *e_info)
|
||||
* 1) nosourceid==y;
|
||||
* 2) bus id is equal to 0. Some ports might lose the bus
|
||||
* id of error source id;
|
||||
* 3) There are multiple errors and prior id comparing fails;
|
||||
* 3) bus flag PCI_BUS_FLAGS_NO_AERSID is set
|
||||
* 4) There are multiple errors and prior ID comparing fails;
|
||||
* We check AER status registers to find possible reporter.
|
||||
*/
|
||||
if (atomic_read(&dev->enable_cnt) == 0)
|
||||
|
@ -189,6 +189,7 @@ typedef unsigned short __bitwise pci_bus_flags_t;
|
||||
enum pci_bus_flags {
|
||||
PCI_BUS_FLAGS_NO_MSI = (__force pci_bus_flags_t) 1,
|
||||
PCI_BUS_FLAGS_NO_MMRBC = (__force pci_bus_flags_t) 2,
|
||||
PCI_BUS_FLAGS_NO_AERSID = (__force pci_bus_flags_t) 4,
|
||||
};
|
||||
|
||||
/* These values come from the PCI Express Spec */
|
||||
|
Loading…
Reference in New Issue
Block a user