forked from luck/tmp_suning_uos_patched
cpufreq: cpufreq-dt: disable unsupported OPPs
If the regulator connected to the CPU voltage plane doesn't support an OPP specified voltage with the acceptable tolerance it's better to just disable the OPP instead of constantly failing the voltage scaling later on. Includes a fix to move initialization of opp_freq outside the loop to avoid an endless loop from Geert Uytterhoeven. Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Signed-off-by: Lucas Stach <l.stach@pengutronix.de> Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
This commit is contained in:
parent
cac7f24298
commit
045ee45c4f
|
@ -187,6 +187,7 @@ static int cpufreq_init(struct cpufreq_policy *policy)
|
|||
struct device *cpu_dev;
|
||||
struct regulator *cpu_reg;
|
||||
struct clk *cpu_clk;
|
||||
unsigned long min_uV = ~0, max_uV = 0;
|
||||
unsigned int transition_latency;
|
||||
int ret;
|
||||
|
||||
|
@ -206,16 +207,10 @@ static int cpufreq_init(struct cpufreq_policy *policy)
|
|||
/* OPPs might be populated at runtime, don't check for error here */
|
||||
of_init_opp_table(cpu_dev);
|
||||
|
||||
ret = dev_pm_opp_init_cpufreq_table(cpu_dev, &freq_table);
|
||||
if (ret) {
|
||||
dev_err(cpu_dev, "failed to init cpufreq table: %d\n", ret);
|
||||
goto out_put_node;
|
||||
}
|
||||
|
||||
priv = kzalloc(sizeof(*priv), GFP_KERNEL);
|
||||
if (!priv) {
|
||||
ret = -ENOMEM;
|
||||
goto out_free_table;
|
||||
goto out_put_node;
|
||||
}
|
||||
|
||||
of_property_read_u32(np, "voltage-tolerance", &priv->voltage_tolerance);
|
||||
|
@ -224,30 +219,51 @@ static int cpufreq_init(struct cpufreq_policy *policy)
|
|||
transition_latency = CPUFREQ_ETERNAL;
|
||||
|
||||
if (!IS_ERR(cpu_reg)) {
|
||||
struct dev_pm_opp *opp;
|
||||
unsigned long min_uV, max_uV;
|
||||
int i;
|
||||
unsigned long opp_freq = 0;
|
||||
|
||||
/*
|
||||
* OPP is maintained in order of increasing frequency, and
|
||||
* freq_table initialised from OPP is therefore sorted in the
|
||||
* same order.
|
||||
* Disable any OPPs where the connected regulator isn't able to
|
||||
* provide the specified voltage and record minimum and maximum
|
||||
* voltage levels.
|
||||
*/
|
||||
for (i = 0; freq_table[i].frequency != CPUFREQ_TABLE_END; i++)
|
||||
;
|
||||
rcu_read_lock();
|
||||
opp = dev_pm_opp_find_freq_exact(cpu_dev,
|
||||
freq_table[0].frequency * 1000, true);
|
||||
min_uV = dev_pm_opp_get_voltage(opp);
|
||||
opp = dev_pm_opp_find_freq_exact(cpu_dev,
|
||||
freq_table[i-1].frequency * 1000, true);
|
||||
max_uV = dev_pm_opp_get_voltage(opp);
|
||||
rcu_read_unlock();
|
||||
while (1) {
|
||||
struct dev_pm_opp *opp;
|
||||
unsigned long opp_uV, tol_uV;
|
||||
|
||||
rcu_read_lock();
|
||||
opp = dev_pm_opp_find_freq_ceil(cpu_dev, &opp_freq);
|
||||
if (IS_ERR(opp)) {
|
||||
rcu_read_unlock();
|
||||
break;
|
||||
}
|
||||
opp_uV = dev_pm_opp_get_voltage(opp);
|
||||
rcu_read_unlock();
|
||||
|
||||
tol_uV = opp_uV * priv->voltage_tolerance / 100;
|
||||
if (regulator_is_supported_voltage(cpu_reg, opp_uV,
|
||||
opp_uV + tol_uV)) {
|
||||
if (opp_uV < min_uV)
|
||||
min_uV = opp_uV;
|
||||
if (opp_uV > max_uV)
|
||||
max_uV = opp_uV;
|
||||
} else {
|
||||
dev_pm_opp_disable(cpu_dev, opp_freq);
|
||||
}
|
||||
|
||||
opp_freq++;
|
||||
}
|
||||
|
||||
ret = regulator_set_voltage_time(cpu_reg, min_uV, max_uV);
|
||||
if (ret > 0)
|
||||
transition_latency += ret * 1000;
|
||||
}
|
||||
|
||||
ret = dev_pm_opp_init_cpufreq_table(cpu_dev, &freq_table);
|
||||
if (ret) {
|
||||
pr_err("failed to init cpufreq table: %d\n", ret);
|
||||
goto out_free_priv;
|
||||
}
|
||||
|
||||
/*
|
||||
* For now, just loading the cooling device;
|
||||
* thermal DT code takes care of matching them.
|
||||
|
@ -286,9 +302,9 @@ static int cpufreq_init(struct cpufreq_policy *policy)
|
|||
|
||||
out_cooling_unregister:
|
||||
cpufreq_cooling_unregister(priv->cdev);
|
||||
kfree(priv);
|
||||
out_free_table:
|
||||
dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);
|
||||
out_free_priv:
|
||||
kfree(priv);
|
||||
out_put_node:
|
||||
of_node_put(np);
|
||||
out_put_reg_clk:
|
||||
|
|
Loading…
Reference in New Issue
Block a user