forked from luck/tmp_suning_uos_patched
perf: Add Arm CMN-600 PMU driver
Initial driver for PMU event counting on the Arm CMN-600 interconnect. CMN sports an obnoxiously complex distributed PMU system as part of its debug and trace features, which can do all manner of things like sampling, cross-triggering and generating CoreSight trace. This driver covers the PMU functionality, plus the relevant aspects of watchpoints for simply counting matching flits. Tested-by: Tsahi Zidenberg <tsahee@amazon.com> Tested-by: Tuan Phan <tuanphan@os.amperecomputing.com> Signed-off-by: Robin Murphy <robin.murphy@arm.com> Signed-off-by: Will Deacon <will@kernel.org>
This commit is contained in:
parent
c8fdbbfa98
commit
0ba64770a2
65
Documentation/admin-guide/perf/arm-cmn.rst
Normal file
65
Documentation/admin-guide/perf/arm-cmn.rst
Normal file
|
@ -0,0 +1,65 @@
|
|||
=============================
|
||||
Arm Coherent Mesh Network PMU
|
||||
=============================
|
||||
|
||||
CMN-600 is a configurable mesh interconnect consisting of a rectangular
|
||||
grid of crosspoints (XPs), with each crosspoint supporting up to two
|
||||
device ports to which various AMBA CHI agents are attached.
|
||||
|
||||
CMN implements a distributed PMU design as part of its debug and trace
|
||||
functionality. This consists of a local monitor (DTM) at every XP, which
|
||||
counts up to 4 event signals from the connected device nodes and/or the
|
||||
XP itself. Overflow from these local counters is accumulated in up to 8
|
||||
global counters implemented by the main controller (DTC), which provides
|
||||
overall PMU control and interrupts for global counter overflow.
|
||||
|
||||
PMU events
|
||||
----------
|
||||
|
||||
The PMU driver registers a single PMU device for the whole interconnect,
|
||||
see /sys/bus/event_source/devices/arm_cmn. Multi-chip systems may link
|
||||
more than one CMN together via external CCIX links - in this situation,
|
||||
each mesh counts its own events entirely independently, and additional
|
||||
PMU devices will be named arm_cmn_{1..n}.
|
||||
|
||||
Most events are specified in a format based directly on the TRM
|
||||
definitions - "type" selects the respective node type, and "eventid" the
|
||||
event number. Some events require an additional occupancy ID, which is
|
||||
specified by "occupid".
|
||||
|
||||
* Since RN-D nodes do not have any distinct events from RN-I nodes, they
|
||||
are treated as the same type (0xa), and the common event templates are
|
||||
named "rnid_*".
|
||||
|
||||
* The cycle counter is treated as a synthetic event belonging to the DTC
|
||||
node ("type" == 0x3, "eventid" is ignored).
|
||||
|
||||
* XP events also encode the port and channel in the "eventid" field, to
|
||||
match the underlying pmu_event0_id encoding for the pmu_event_sel
|
||||
register. The event templates are named with prefixes to cover all
|
||||
permutations.
|
||||
|
||||
By default each event provides an aggregate count over all nodes of the
|
||||
given type. To target a specific node, "bynodeid" must be set to 1 and
|
||||
"nodeid" to the appropriate value derived from the CMN configuration
|
||||
(as defined in the "Node ID Mapping" section of the TRM).
|
||||
|
||||
Watchpoints
|
||||
-----------
|
||||
|
||||
The PMU can also count watchpoint events to monitor specific flit
|
||||
traffic. Watchpoints are treated as a synthetic event type, and like PMU
|
||||
events can be global or targeted with a particular XP's "nodeid" value.
|
||||
Since the watchpoint direction is otherwise implicit in the underlying
|
||||
register selection, separate events are provided for flit uploads and
|
||||
downloads.
|
||||
|
||||
The flit match value and mask are passed in config1 and config2 ("val"
|
||||
and "mask" respectively). "wp_dev_sel", "wp_chn_sel", "wp_grp" and
|
||||
"wp_exclusive" are specified per the TRM definitions for dtm_wp_config0.
|
||||
Where a watchpoint needs to match fields from both match groups on the
|
||||
REQ or SNP channel, it can be specified as two events - one for each
|
||||
group - with the same nonzero "combine" value. The count for such a
|
||||
pair of combined events will be attributed to the primary match.
|
||||
Watchpoint events with a "combine" value of 0 are considered independent
|
||||
and will count individually.
|
|
@ -12,6 +12,7 @@ Performance monitor support
|
|||
qcom_l2_pmu
|
||||
qcom_l3_pmu
|
||||
arm-ccn
|
||||
arm-cmn
|
||||
xgene-pmu
|
||||
arm_dsu_pmu
|
||||
thunderx2-pmu
|
||||
|
|
|
@ -41,6 +41,13 @@ config ARM_CCN
|
|||
PMU (perf) driver supporting the ARM CCN (Cache Coherent Network)
|
||||
interconnect.
|
||||
|
||||
config ARM_CMN
|
||||
tristate "Arm CMN-600 PMU support"
|
||||
depends on ARM64 || (COMPILE_TEST && 64BIT)
|
||||
help
|
||||
Support for PMU events monitoring on the Arm CMN-600 Coherent Mesh
|
||||
Network interconnect.
|
||||
|
||||
config ARM_PMU
|
||||
depends on ARM || ARM64
|
||||
bool "ARM PMU framework"
|
||||
|
|
|
@ -1,6 +1,7 @@
|
|||
# SPDX-License-Identifier: GPL-2.0
|
||||
obj-$(CONFIG_ARM_CCI_PMU) += arm-cci.o
|
||||
obj-$(CONFIG_ARM_CCN) += arm-ccn.o
|
||||
obj-$(CONFIG_ARM_CMN) += arm-cmn.o
|
||||
obj-$(CONFIG_ARM_DSU_PMU) += arm_dsu_pmu.o
|
||||
obj-$(CONFIG_ARM_PMU) += arm_pmu.o arm_pmu_platform.o
|
||||
obj-$(CONFIG_ARM_PMU_ACPI) += arm_pmu_acpi.o
|
||||
|
|
1641
drivers/perf/arm-cmn.c
Normal file
1641
drivers/perf/arm-cmn.c
Normal file
File diff suppressed because it is too large
Load Diff
Loading…
Reference in New Issue
Block a user