forked from luck/tmp_suning_uos_patched
bnx2x: fix cl_id allocation for non-eth clients for NPAR mode
There are some consolidations of NPAR configuration when FCoE and iSCSI L2 clients will get the same id, in this case FCoE ring will be non-functional. Signed-off-by: Dmitry Kravkov <dmitry@broadcom.com> Signed-off-by: Eilon Greenstein <eilong@broadcom.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
c5d6136e10
commit
134d0f974c
|
@ -239,13 +239,19 @@ void bnx2x_int_disable(struct bnx2x *bp);
|
|||
* FUNC_N_CLID_X = N * NUM_SPECIAL_CLIENTS + FUNC_0_CLID_X
|
||||
*
|
||||
*/
|
||||
/* iSCSI L2 */
|
||||
#define BNX2X_ISCSI_ETH_CL_ID_IDX 1
|
||||
#define BNX2X_ISCSI_ETH_CID 49
|
||||
enum {
|
||||
BNX2X_ISCSI_ETH_CL_ID_IDX,
|
||||
BNX2X_FCOE_ETH_CL_ID_IDX,
|
||||
BNX2X_MAX_CNIC_ETH_CL_ID_IDX,
|
||||
};
|
||||
|
||||
/* FCoE L2 */
|
||||
#define BNX2X_FCOE_ETH_CL_ID_IDX 2
|
||||
#define BNX2X_FCOE_ETH_CID 50
|
||||
#define BNX2X_CNIC_START_ETH_CID 48
|
||||
enum {
|
||||
/* iSCSI L2 */
|
||||
BNX2X_ISCSI_ETH_CID = BNX2X_CNIC_START_ETH_CID,
|
||||
/* FCoE L2 */
|
||||
BNX2X_FCOE_ETH_CID,
|
||||
};
|
||||
|
||||
/** Additional rings budgeting */
|
||||
#ifdef BCM_CNIC
|
||||
|
|
|
@ -1297,7 +1297,7 @@ static inline void bnx2x_init_txdata(struct bnx2x *bp,
|
|||
static inline u8 bnx2x_cnic_eth_cl_id(struct bnx2x *bp, u8 cl_idx)
|
||||
{
|
||||
return bp->cnic_base_cl_id + cl_idx +
|
||||
(bp->pf_num >> 1) * NON_ETH_CONTEXT_USE;
|
||||
(bp->pf_num >> 1) * BNX2X_MAX_CNIC_ETH_CL_ID_IDX;
|
||||
}
|
||||
|
||||
static inline u8 bnx2x_cnic_fw_sb_id(struct bnx2x *bp)
|
||||
|
|
Loading…
Reference in New Issue
Block a user