forked from luck/tmp_suning_uos_patched
[SCSI] zfcp: Fix oops during shutdown of offline device
With the change that the zfcp_adapter struct is only allocated when the device is set online, the shutdown handler has to check for a non-existing zfcp_adapter struct. On the other hand, this check is not necessary in the offline callback, since an online device has the zfcp_adapter allocated and we go through the offline callback before removing the ccw device. Reviewed-by: Felix Beck <felix.beck@de.ibm.com> Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This commit is contained in:
parent
c5afd81e5d
commit
1f99bd4cbf
@ -192,13 +192,9 @@ static int zfcp_ccw_set_offline(struct ccw_device *ccw_device)
|
||||
|
||||
mutex_lock(&zfcp_data.config_mutex);
|
||||
adapter = dev_get_drvdata(&ccw_device->dev);
|
||||
if (!adapter)
|
||||
goto out;
|
||||
|
||||
zfcp_erp_adapter_shutdown(adapter, 0, "ccsoff1", NULL);
|
||||
zfcp_erp_wait(adapter);
|
||||
mutex_unlock(&zfcp_data.config_mutex);
|
||||
out:
|
||||
return 0;
|
||||
}
|
||||
|
||||
@ -253,9 +249,13 @@ static void zfcp_ccw_shutdown(struct ccw_device *cdev)
|
||||
|
||||
mutex_lock(&zfcp_data.config_mutex);
|
||||
adapter = dev_get_drvdata(&cdev->dev);
|
||||
if (!adapter)
|
||||
goto out;
|
||||
|
||||
zfcp_erp_adapter_shutdown(adapter, 0, "ccshut1", NULL);
|
||||
zfcp_erp_wait(adapter);
|
||||
zfcp_erp_thread_kill(adapter);
|
||||
out:
|
||||
mutex_unlock(&zfcp_data.config_mutex);
|
||||
}
|
||||
|
||||
|