forked from luck/tmp_suning_uos_patched
md/raid5: ensure correct assessment of drives during degraded reshape.
While reshaping a degraded array (as when reshaping a RAID0 by first converting it to a degraded RAID4) we currently get confused about which devices are in_sync. In most cases we get it right, but in the region that is being reshaped we need to treat non-failed devices as in-sync when we have the data but haven't actually written it out yet. Reported-by: Adam Kwolek <adam.kwolek@intel.com> Signed-off-by: NeilBrown <neilb@suse.de>
This commit is contained in:
parent
09cd9270ea
commit
30d7a48368
@ -3065,11 +3065,17 @@ static void analyse_stripe(struct stripe_head *sh, struct stripe_head_state *s)
|
||||
}
|
||||
} else if (test_bit(In_sync, &rdev->flags))
|
||||
set_bit(R5_Insync, &dev->flags);
|
||||
else {
|
||||
else if (sh->sector + STRIPE_SECTORS <= rdev->recovery_offset)
|
||||
/* in sync if before recovery_offset */
|
||||
if (sh->sector + STRIPE_SECTORS <= rdev->recovery_offset)
|
||||
set_bit(R5_Insync, &dev->flags);
|
||||
}
|
||||
set_bit(R5_Insync, &dev->flags);
|
||||
else if (test_bit(R5_UPTODATE, &dev->flags) &&
|
||||
test_bit(R5_Expanded, &dev->flags))
|
||||
/* If we've reshaped into here, we assume it is Insync.
|
||||
* We will shortly update recovery_offset to make
|
||||
* it official.
|
||||
*/
|
||||
set_bit(R5_Insync, &dev->flags);
|
||||
|
||||
if (rdev && test_bit(R5_WriteError, &dev->flags)) {
|
||||
clear_bit(R5_Insync, &dev->flags);
|
||||
if (!test_bit(Faulty, &rdev->flags)) {
|
||||
|
Loading…