forked from luck/tmp_suning_uos_patched
power: supply: core: Add power_supply_prop_precharge
Battery chargers use POWER_SUPPLY_PROP_PRECHARGE_CURRENT Clarify related item POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT Signed-off-by: Liam Breck <kernel@networkimprov.net> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
This commit is contained in:
parent
c08b1f45d7
commit
413de34ab9
|
@ -115,28 +115,33 @@ of charge when battery became full/empty". It also could mean "value of
|
|||
charge when battery considered full/empty at given conditions (temperature,
|
||||
age)". I.e. these attributes represents real thresholds, not design values.
|
||||
|
||||
ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
|
||||
|
||||
CHARGE_COUNTER - the current charge counter (in µAh). This could easily
|
||||
be negative; there is no empty or full value. It is only useful for
|
||||
relative, time-based measurements.
|
||||
|
||||
PRECHARGE_CURRENT - the maximum charge current during precharge phase
|
||||
of charge cycle (typically 20% of battery capacity).
|
||||
CHARGE_TERM_CURRENT - Charge termination current. The charge cycle
|
||||
terminates when battery voltage is above recharge threshold, and charge
|
||||
current is below this setting (typically 10% of battery capacity).
|
||||
|
||||
CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger.
|
||||
CONSTANT_CHARGE_CURRENT_MAX - maximum charge current supported by the
|
||||
power supply object.
|
||||
INPUT_CURRENT_LIMIT - input current limit programmed by charger. Indicates
|
||||
the current drawn from a charging source.
|
||||
CHARGE_TERM_CURRENT - Charge termination current used to detect the end of charge
|
||||
condition.
|
||||
|
||||
CALIBRATE - battery or coulomb counter calibration status
|
||||
|
||||
CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger.
|
||||
CONSTANT_CHARGE_VOLTAGE_MAX - maximum charge voltage supported by the
|
||||
power supply object.
|
||||
|
||||
INPUT_CURRENT_LIMIT - input current limit programmed by charger. Indicates
|
||||
the current drawn from a charging source.
|
||||
|
||||
CHARGE_CONTROL_LIMIT - current charge control limit setting
|
||||
CHARGE_CONTROL_LIMIT_MAX - maximum charge control limit setting
|
||||
|
||||
ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
|
||||
CALIBRATE - battery or coulomb counter calibration status
|
||||
|
||||
CAPACITY - capacity in percents.
|
||||
CAPACITY_ALERT_MIN - minimum capacity alert value in percents.
|
||||
|
|
|
@ -242,6 +242,7 @@ static struct device_attribute power_supply_attrs[] = {
|
|||
POWER_SUPPLY_ATTR(time_to_full_avg),
|
||||
POWER_SUPPLY_ATTR(type),
|
||||
POWER_SUPPLY_ATTR(scope),
|
||||
POWER_SUPPLY_ATTR(precharge_current),
|
||||
POWER_SUPPLY_ATTR(charge_term_current),
|
||||
POWER_SUPPLY_ATTR(calibrate),
|
||||
/* Properties of type `const char *' */
|
||||
|
|
|
@ -146,6 +146,7 @@ enum power_supply_property {
|
|||
POWER_SUPPLY_PROP_TIME_TO_FULL_AVG,
|
||||
POWER_SUPPLY_PROP_TYPE, /* use power_supply.type instead */
|
||||
POWER_SUPPLY_PROP_SCOPE,
|
||||
POWER_SUPPLY_PROP_PRECHARGE_CURRENT,
|
||||
POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT,
|
||||
POWER_SUPPLY_PROP_CALIBRATE,
|
||||
/* Properties of type `const char *' */
|
||||
|
@ -382,6 +383,8 @@ static inline bool power_supply_is_amp_property(enum power_supply_property psp)
|
|||
case POWER_SUPPLY_PROP_CHARGE_NOW:
|
||||
case POWER_SUPPLY_PROP_CHARGE_AVG:
|
||||
case POWER_SUPPLY_PROP_CHARGE_COUNTER:
|
||||
case POWER_SUPPLY_PROP_PRECHARGE_CURRENT:
|
||||
case POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT:
|
||||
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT:
|
||||
case POWER_SUPPLY_PROP_CONSTANT_CHARGE_CURRENT_MAX:
|
||||
case POWER_SUPPLY_PROP_CURRENT_MAX:
|
||||
|
|
Loading…
Reference in New Issue
Block a user