forked from luck/tmp_suning_uos_patched
arm64: dts: clearfog-gt-8k: fix switch link configuration
The commit below caused a regression for clearfog-gt-8k, where the link
between the switch and the host does not come up.
Investigation revealed two issues:
- MV88E6xxx DSA no longer allows an in-band link to come up as the link
is programmed to be forced down. Commit "net: dsa: mv88e6xxx: fix
in-band AN link establishment" addresses this.
- The dts configured dissimilar link modes at each end of the host to
switch link; the host was configured using a fixed link (so has no
in-band status) and the switch was configured to expect in-band
status.
With both issues fixed, the regression is resolved.
Fixes: 34b5e6a33c
("net: dsa: mv88e6xxx: Configure MAC when using fixed link")
Reported-by: Martin Rowe <martin.p.rowe@gmail.com>
Signed-off-by: Russell King <rmk+kernel@armlinux.org.uk>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>