forked from luck/tmp_suning_uos_patched
target: Don't call TFO->write_pending if data_length == 0
If an initiator sends a zero-length command (e.g. TEST UNIT READY) but sets the transfer direction in the transport layer to indicate a data-out phase, we still shouldn't try to transfer data. At best it's a NOP, and depending on the transport, we might crash on an uninitialized sg list. Reported-by: Craig Watson <craig.watson@vanguard-rugged.com> Signed-off-by: Roland Dreier <roland@purestorage.com> Cc: <stable@vger.kernel.org> # 3.1 Signed-off-by: Nicholas Bellinger <nab@linux-iscsi.org>
This commit is contained in:
parent
cac7f24298
commit
885e7b0e18
@ -2292,7 +2292,7 @@ transport_generic_new_cmd(struct se_cmd *cmd)
|
||||
* and let it call back once the write buffers are ready.
|
||||
*/
|
||||
target_add_to_state_list(cmd);
|
||||
if (cmd->data_direction != DMA_TO_DEVICE) {
|
||||
if (cmd->data_direction != DMA_TO_DEVICE || cmd->data_length == 0) {
|
||||
target_execute_cmd(cmd);
|
||||
return 0;
|
||||
}
|
||||
|
Loading…