regulator: lp3972: Convert to use regulator_map_voltage_ascend

All regulators have ascendant voltage list in this driver.
Thus use regulator_map_voltage_ascend is more efficient than the default
regulator_map_voltage_iterate.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Axel Lin 2013-04-21 00:36:56 +08:00 committed by Mark Brown
parent 3e655618e1
commit b50003b69d

View File

@ -309,6 +309,7 @@ static int lp3972_ldo_set_voltage_sel(struct regulator_dev *dev,
static struct regulator_ops lp3972_ldo_ops = {
.list_voltage = regulator_list_voltage_table,
.map_voltage = regulator_map_voltage_ascend,
.is_enabled = lp3972_ldo_is_enabled,
.enable = lp3972_ldo_enable,
.disable = lp3972_ldo_disable,
@ -389,6 +390,7 @@ static int lp3972_dcdc_set_voltage_sel(struct regulator_dev *dev,
static struct regulator_ops lp3972_dcdc_ops = {
.list_voltage = regulator_list_voltage_table,
.map_voltage = regulator_map_voltage_ascend,
.is_enabled = lp3972_dcdc_is_enabled,
.enable = lp3972_dcdc_enable,
.disable = lp3972_dcdc_disable,