rtc: hym8563: fix invalid year calculation

Year field must be in BCD format, according to
hym8563 datasheet.

Due to the bug year 2016 became 2010.

Fixes: dcaf038493 ("rtc: add hym8563 rtc-driver")
Signed-off-by: Alexander Kochetkov <al.kochet@gmail.com>
Signed-off-by: Alexandre Belloni <alexandre.belloni@free-electrons.com>
This commit is contained in:
Alexander Kochetkov 2016-03-06 12:43:57 +03:00 committed by Alexandre Belloni
parent fc1dcb0b39
commit d586126221

View File

@ -144,7 +144,7 @@ static int hym8563_rtc_set_time(struct device *dev, struct rtc_time *tm)
* it does not seem to carry it over a subsequent write/read. * it does not seem to carry it over a subsequent write/read.
* So we'll limit ourself to 100 years, starting at 2000 for now. * So we'll limit ourself to 100 years, starting at 2000 for now.
*/ */
buf[6] = tm->tm_year - 100; buf[6] = bin2bcd(tm->tm_year - 100);
/* /*
* CTL1 only contains TEST-mode bits apart from stop, * CTL1 only contains TEST-mode bits apart from stop,