qla2xxx: Fix endianness of task management response code

The qla2xxx firmware actually expects the task management response
code in a CTIO IOCB with SCSI status mode 1 to be in little-endian
byte order, ie the response code should be the first byte in the
sense_data[] array.  The old code erroneously byte-swapped the
response code, which puts it in the wrong place on the wire and leads
to initiators thinking every task management request succeeds (since
they see 0 in the byte where they look for the response code).

Signed-off-by: Roland Dreier <roland@purestorage.com>
Cc: Chad Dupuis <chad.dupuis@qlogic.com>
Cc: Arun Easi <arun.easi@qlogic.com>
Acked-by: Saurav Kashyap <saurav.kashyap@qlogic.com>
Cc: stable@vger.kernel.org
Signed-off-by: Nicholas Bellinger <nab@linux-iscsi.org>
This commit is contained in:
Roland Dreier 2012-09-18 15:10:56 -07:00 committed by Nicholas Bellinger
parent 37bb7899ca
commit e4b11b89f9

View File

@ -1403,7 +1403,7 @@ static void qlt_24xx_send_task_mgmt_ctio(struct scsi_qla_host *ha,
ctio->u.status1.scsi_status =
__constant_cpu_to_le16(SS_RESPONSE_INFO_LEN_VALID);
ctio->u.status1.response_len = __constant_cpu_to_le16(8);
((uint32_t *)ctio->u.status1.sense_data)[0] = cpu_to_be32(resp_code);
ctio->u.status1.sense_data[0] = resp_code;
qla2x00_start_iocbs(ha, ha->req);
}