[ Upstream commit d8a441e53e2434b1401e52dfd66b05263e442edc ]
In order that the end of a clk_div_table can be detected, it must be
terminated with a sentinel element (.div = 0).
In owl-s900.s, the { 0, 8 } element was probably meant to be just that,
so this patch changes { 0, 8 } to { 0, 0 }.
Fixes: d47317ca4a ("clk: actions: Add S700 SoC clock support")
Fixes: d85d20053e ("clk: actions: Add S900 SoC clock support")
Signed-off-by: Jonathan Neuschäfer <j.neuschaefer@gmx.net>
Reviewed-by: Manivannan Sadhasivam <mani@kernel.org>
Link: https://lore.kernel.org/r/20220218000922.134857-2-j.neuschaefer@gmx.net
Signed-off-by: Stephen Boyd <sboyd@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>