forked from luck/tmp_suning_uos_patched
af4e1c5eca
The AMD Ryzen gen 3 processors came with a different PCI IDs for the function 3 & 4 which are used to access the SMN interface. The root PCI address however remained at the same address as the model 30h. Adding the F3/F4 PCI IDs respectively to the misc and link ids appear to be sufficient for k10temp, so let's add them and follow up on the patch if other functions need more tweaking. Vicki Pfau sent an identical patch after I checked that no-one had written this patch. I would have been happy about dropping my patch but unlike for his patch series, I had already Cc:ed the x86 people and they already reviewed the changes. Since Vicki has not answered to any email after his initial series, let's assume she is on vacation and let's avoid duplication of reviews from the maintainers and merge my series. To acknowledge Vicki's anteriority, I added her S-o-b to the patch. v2, suggested by Guenter Roeck and Brian Woods: - rename from 71h to 70h Signed-off-by: Vicki Pfau <vi@endrift.com> Signed-off-by: Marcel Bocu <marcel.p.bocu@gmail.com> Tested-by: Marcel Bocu <marcel.p.bocu@gmail.com> Acked-by: Thomas Gleixner <tglx@linutronix.de> Acked-by: Brian Woods <brian.woods@amd.com> Acked-by: Bjorn Helgaas <bhelgaas@google.com> # pci_ids.h Cc: Thomas Gleixner <tglx@linutronix.de> Cc: Ingo Molnar <mingo@redhat.com> Cc: Borislav Petkov <bp@alien8.de> Cc: "H. Peter Anvin" <hpa@zytor.com> Cc: x86@kernel.org Cc: "Woods, Brian" <Brian.Woods@amd.com> Cc: Clemens Ladisch <clemens@ladisch.de> Cc: Jean Delvare <jdelvare@suse.com> Cc: Guenter Roeck <linux@roeck-us.net> Cc: linux-hwmon@vger.kernel.org Link: https://lore.kernel.org/r/20190722174510.2179-1-marcel.p.bocu@gmail.com Signed-off-by: Guenter Roeck <linux@roeck-us.net>
536 lines
14 KiB
C
536 lines
14 KiB
C
// SPDX-License-Identifier: GPL-2.0-only
|
|
/*
|
|
* Shared support code for AMD K8 northbridges and derivates.
|
|
* Copyright 2006 Andi Kleen, SUSE Labs.
|
|
*/
|
|
|
|
#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt
|
|
|
|
#include <linux/types.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/init.h>
|
|
#include <linux/errno.h>
|
|
#include <linux/export.h>
|
|
#include <linux/spinlock.h>
|
|
#include <linux/pci_ids.h>
|
|
#include <asm/amd_nb.h>
|
|
|
|
#define PCI_DEVICE_ID_AMD_17H_ROOT 0x1450
|
|
#define PCI_DEVICE_ID_AMD_17H_M10H_ROOT 0x15d0
|
|
#define PCI_DEVICE_ID_AMD_17H_M30H_ROOT 0x1480
|
|
#define PCI_DEVICE_ID_AMD_17H_DF_F4 0x1464
|
|
#define PCI_DEVICE_ID_AMD_17H_M10H_DF_F4 0x15ec
|
|
#define PCI_DEVICE_ID_AMD_17H_M30H_DF_F4 0x1494
|
|
#define PCI_DEVICE_ID_AMD_17H_M70H_DF_F4 0x1444
|
|
|
|
/* Protect the PCI config register pairs used for SMN and DF indirect access. */
|
|
static DEFINE_MUTEX(smn_mutex);
|
|
|
|
static u32 *flush_words;
|
|
|
|
static const struct pci_device_id amd_root_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_ROOT) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M10H_ROOT) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M30H_ROOT) },
|
|
{}
|
|
};
|
|
|
|
|
|
#define PCI_DEVICE_ID_AMD_CNB17H_F4 0x1704
|
|
|
|
const struct pci_device_id amd_nb_misc_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_K8_NB_MISC) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_10H_NB_MISC) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M10H_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M30H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M60H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_M30H_NB_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_DF_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M10H_DF_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M30H_DF_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_CNB17H_F3) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M70H_DF_F3) },
|
|
{}
|
|
};
|
|
EXPORT_SYMBOL_GPL(amd_nb_misc_ids);
|
|
|
|
static const struct pci_device_id amd_nb_link_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M30H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_15H_M60H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_16H_M30H_NB_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_DF_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M10H_DF_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M30H_DF_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_17H_M70H_DF_F4) },
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_AMD, PCI_DEVICE_ID_AMD_CNB17H_F4) },
|
|
{}
|
|
};
|
|
|
|
static const struct pci_device_id hygon_root_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_HYGON, PCI_DEVICE_ID_AMD_17H_ROOT) },
|
|
{}
|
|
};
|
|
|
|
static const struct pci_device_id hygon_nb_misc_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_HYGON, PCI_DEVICE_ID_AMD_17H_DF_F3) },
|
|
{}
|
|
};
|
|
|
|
static const struct pci_device_id hygon_nb_link_ids[] = {
|
|
{ PCI_DEVICE(PCI_VENDOR_ID_HYGON, PCI_DEVICE_ID_AMD_17H_DF_F4) },
|
|
{}
|
|
};
|
|
|
|
const struct amd_nb_bus_dev_range amd_nb_bus_dev_ranges[] __initconst = {
|
|
{ 0x00, 0x18, 0x20 },
|
|
{ 0xff, 0x00, 0x20 },
|
|
{ 0xfe, 0x00, 0x20 },
|
|
{ }
|
|
};
|
|
|
|
static struct amd_northbridge_info amd_northbridges;
|
|
|
|
u16 amd_nb_num(void)
|
|
{
|
|
return amd_northbridges.num;
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_nb_num);
|
|
|
|
bool amd_nb_has_feature(unsigned int feature)
|
|
{
|
|
return ((amd_northbridges.flags & feature) == feature);
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_nb_has_feature);
|
|
|
|
struct amd_northbridge *node_to_amd_nb(int node)
|
|
{
|
|
return (node < amd_northbridges.num) ? &amd_northbridges.nb[node] : NULL;
|
|
}
|
|
EXPORT_SYMBOL_GPL(node_to_amd_nb);
|
|
|
|
static struct pci_dev *next_northbridge(struct pci_dev *dev,
|
|
const struct pci_device_id *ids)
|
|
{
|
|
do {
|
|
dev = pci_get_device(PCI_ANY_ID, PCI_ANY_ID, dev);
|
|
if (!dev)
|
|
break;
|
|
} while (!pci_match_id(ids, dev));
|
|
return dev;
|
|
}
|
|
|
|
static int __amd_smn_rw(u16 node, u32 address, u32 *value, bool write)
|
|
{
|
|
struct pci_dev *root;
|
|
int err = -ENODEV;
|
|
|
|
if (node >= amd_northbridges.num)
|
|
goto out;
|
|
|
|
root = node_to_amd_nb(node)->root;
|
|
if (!root)
|
|
goto out;
|
|
|
|
mutex_lock(&smn_mutex);
|
|
|
|
err = pci_write_config_dword(root, 0x60, address);
|
|
if (err) {
|
|
pr_warn("Error programming SMN address 0x%x.\n", address);
|
|
goto out_unlock;
|
|
}
|
|
|
|
err = (write ? pci_write_config_dword(root, 0x64, *value)
|
|
: pci_read_config_dword(root, 0x64, value));
|
|
if (err)
|
|
pr_warn("Error %s SMN address 0x%x.\n",
|
|
(write ? "writing to" : "reading from"), address);
|
|
|
|
out_unlock:
|
|
mutex_unlock(&smn_mutex);
|
|
|
|
out:
|
|
return err;
|
|
}
|
|
|
|
int amd_smn_read(u16 node, u32 address, u32 *value)
|
|
{
|
|
return __amd_smn_rw(node, address, value, false);
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_smn_read);
|
|
|
|
int amd_smn_write(u16 node, u32 address, u32 value)
|
|
{
|
|
return __amd_smn_rw(node, address, &value, true);
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_smn_write);
|
|
|
|
/*
|
|
* Data Fabric Indirect Access uses FICAA/FICAD.
|
|
*
|
|
* Fabric Indirect Configuration Access Address (FICAA): Constructed based
|
|
* on the device's Instance Id and the PCI function and register offset of
|
|
* the desired register.
|
|
*
|
|
* Fabric Indirect Configuration Access Data (FICAD): There are FICAD LO
|
|
* and FICAD HI registers but so far we only need the LO register.
|
|
*/
|
|
int amd_df_indirect_read(u16 node, u8 func, u16 reg, u8 instance_id, u32 *lo)
|
|
{
|
|
struct pci_dev *F4;
|
|
u32 ficaa;
|
|
int err = -ENODEV;
|
|
|
|
if (node >= amd_northbridges.num)
|
|
goto out;
|
|
|
|
F4 = node_to_amd_nb(node)->link;
|
|
if (!F4)
|
|
goto out;
|
|
|
|
ficaa = 1;
|
|
ficaa |= reg & 0x3FC;
|
|
ficaa |= (func & 0x7) << 11;
|
|
ficaa |= instance_id << 16;
|
|
|
|
mutex_lock(&smn_mutex);
|
|
|
|
err = pci_write_config_dword(F4, 0x5C, ficaa);
|
|
if (err) {
|
|
pr_warn("Error writing DF Indirect FICAA, FICAA=0x%x\n", ficaa);
|
|
goto out_unlock;
|
|
}
|
|
|
|
err = pci_read_config_dword(F4, 0x98, lo);
|
|
if (err)
|
|
pr_warn("Error reading DF Indirect FICAD LO, FICAA=0x%x.\n", ficaa);
|
|
|
|
out_unlock:
|
|
mutex_unlock(&smn_mutex);
|
|
|
|
out:
|
|
return err;
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_df_indirect_read);
|
|
|
|
int amd_cache_northbridges(void)
|
|
{
|
|
const struct pci_device_id *misc_ids = amd_nb_misc_ids;
|
|
const struct pci_device_id *link_ids = amd_nb_link_ids;
|
|
const struct pci_device_id *root_ids = amd_root_ids;
|
|
struct pci_dev *root, *misc, *link;
|
|
struct amd_northbridge *nb;
|
|
u16 roots_per_misc = 0;
|
|
u16 misc_count = 0;
|
|
u16 root_count = 0;
|
|
u16 i, j;
|
|
|
|
if (amd_northbridges.num)
|
|
return 0;
|
|
|
|
if (boot_cpu_data.x86_vendor == X86_VENDOR_HYGON) {
|
|
root_ids = hygon_root_ids;
|
|
misc_ids = hygon_nb_misc_ids;
|
|
link_ids = hygon_nb_link_ids;
|
|
}
|
|
|
|
misc = NULL;
|
|
while ((misc = next_northbridge(misc, misc_ids)) != NULL)
|
|
misc_count++;
|
|
|
|
if (!misc_count)
|
|
return -ENODEV;
|
|
|
|
root = NULL;
|
|
while ((root = next_northbridge(root, root_ids)) != NULL)
|
|
root_count++;
|
|
|
|
if (root_count) {
|
|
roots_per_misc = root_count / misc_count;
|
|
|
|
/*
|
|
* There should be _exactly_ N roots for each DF/SMN
|
|
* interface.
|
|
*/
|
|
if (!roots_per_misc || (root_count % roots_per_misc)) {
|
|
pr_info("Unsupported AMD DF/PCI configuration found\n");
|
|
return -ENODEV;
|
|
}
|
|
}
|
|
|
|
nb = kcalloc(misc_count, sizeof(struct amd_northbridge), GFP_KERNEL);
|
|
if (!nb)
|
|
return -ENOMEM;
|
|
|
|
amd_northbridges.nb = nb;
|
|
amd_northbridges.num = misc_count;
|
|
|
|
link = misc = root = NULL;
|
|
for (i = 0; i < amd_northbridges.num; i++) {
|
|
node_to_amd_nb(i)->root = root =
|
|
next_northbridge(root, root_ids);
|
|
node_to_amd_nb(i)->misc = misc =
|
|
next_northbridge(misc, misc_ids);
|
|
node_to_amd_nb(i)->link = link =
|
|
next_northbridge(link, link_ids);
|
|
|
|
/*
|
|
* If there are more PCI root devices than data fabric/
|
|
* system management network interfaces, then the (N)
|
|
* PCI roots per DF/SMN interface are functionally the
|
|
* same (for DF/SMN access) and N-1 are redundant. N-1
|
|
* PCI roots should be skipped per DF/SMN interface so
|
|
* the following DF/SMN interfaces get mapped to
|
|
* correct PCI roots.
|
|
*/
|
|
for (j = 1; j < roots_per_misc; j++)
|
|
root = next_northbridge(root, root_ids);
|
|
}
|
|
|
|
if (amd_gart_present())
|
|
amd_northbridges.flags |= AMD_NB_GART;
|
|
|
|
/*
|
|
* Check for L3 cache presence.
|
|
*/
|
|
if (!cpuid_edx(0x80000006))
|
|
return 0;
|
|
|
|
/*
|
|
* Some CPU families support L3 Cache Index Disable. There are some
|
|
* limitations because of E382 and E388 on family 0x10.
|
|
*/
|
|
if (boot_cpu_data.x86 == 0x10 &&
|
|
boot_cpu_data.x86_model >= 0x8 &&
|
|
(boot_cpu_data.x86_model > 0x9 ||
|
|
boot_cpu_data.x86_stepping >= 0x1))
|
|
amd_northbridges.flags |= AMD_NB_L3_INDEX_DISABLE;
|
|
|
|
if (boot_cpu_data.x86 == 0x15)
|
|
amd_northbridges.flags |= AMD_NB_L3_INDEX_DISABLE;
|
|
|
|
/* L3 cache partitioning is supported on family 0x15 */
|
|
if (boot_cpu_data.x86 == 0x15)
|
|
amd_northbridges.flags |= AMD_NB_L3_PARTITIONING;
|
|
|
|
return 0;
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_cache_northbridges);
|
|
|
|
/*
|
|
* Ignores subdevice/subvendor but as far as I can figure out
|
|
* they're useless anyways
|
|
*/
|
|
bool __init early_is_amd_nb(u32 device)
|
|
{
|
|
const struct pci_device_id *misc_ids = amd_nb_misc_ids;
|
|
const struct pci_device_id *id;
|
|
u32 vendor = device & 0xffff;
|
|
|
|
if (boot_cpu_data.x86_vendor != X86_VENDOR_AMD &&
|
|
boot_cpu_data.x86_vendor != X86_VENDOR_HYGON)
|
|
return false;
|
|
|
|
if (boot_cpu_data.x86_vendor == X86_VENDOR_HYGON)
|
|
misc_ids = hygon_nb_misc_ids;
|
|
|
|
device >>= 16;
|
|
for (id = misc_ids; id->vendor; id++)
|
|
if (vendor == id->vendor && device == id->device)
|
|
return true;
|
|
return false;
|
|
}
|
|
|
|
struct resource *amd_get_mmconfig_range(struct resource *res)
|
|
{
|
|
u32 address;
|
|
u64 base, msr;
|
|
unsigned int segn_busn_bits;
|
|
|
|
if (boot_cpu_data.x86_vendor != X86_VENDOR_AMD &&
|
|
boot_cpu_data.x86_vendor != X86_VENDOR_HYGON)
|
|
return NULL;
|
|
|
|
/* assume all cpus from fam10h have mmconfig */
|
|
if (boot_cpu_data.x86 < 0x10)
|
|
return NULL;
|
|
|
|
address = MSR_FAM10H_MMIO_CONF_BASE;
|
|
rdmsrl(address, msr);
|
|
|
|
/* mmconfig is not enabled */
|
|
if (!(msr & FAM10H_MMIO_CONF_ENABLE))
|
|
return NULL;
|
|
|
|
base = msr & (FAM10H_MMIO_CONF_BASE_MASK<<FAM10H_MMIO_CONF_BASE_SHIFT);
|
|
|
|
segn_busn_bits = (msr >> FAM10H_MMIO_CONF_BUSRANGE_SHIFT) &
|
|
FAM10H_MMIO_CONF_BUSRANGE_MASK;
|
|
|
|
res->flags = IORESOURCE_MEM;
|
|
res->start = base;
|
|
res->end = base + (1ULL<<(segn_busn_bits + 20)) - 1;
|
|
return res;
|
|
}
|
|
|
|
int amd_get_subcaches(int cpu)
|
|
{
|
|
struct pci_dev *link = node_to_amd_nb(amd_get_nb_id(cpu))->link;
|
|
unsigned int mask;
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_L3_PARTITIONING))
|
|
return 0;
|
|
|
|
pci_read_config_dword(link, 0x1d4, &mask);
|
|
|
|
return (mask >> (4 * cpu_data(cpu).cpu_core_id)) & 0xf;
|
|
}
|
|
|
|
int amd_set_subcaches(int cpu, unsigned long mask)
|
|
{
|
|
static unsigned int reset, ban;
|
|
struct amd_northbridge *nb = node_to_amd_nb(amd_get_nb_id(cpu));
|
|
unsigned int reg;
|
|
int cuid;
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_L3_PARTITIONING) || mask > 0xf)
|
|
return -EINVAL;
|
|
|
|
/* if necessary, collect reset state of L3 partitioning and BAN mode */
|
|
if (reset == 0) {
|
|
pci_read_config_dword(nb->link, 0x1d4, &reset);
|
|
pci_read_config_dword(nb->misc, 0x1b8, &ban);
|
|
ban &= 0x180000;
|
|
}
|
|
|
|
/* deactivate BAN mode if any subcaches are to be disabled */
|
|
if (mask != 0xf) {
|
|
pci_read_config_dword(nb->misc, 0x1b8, ®);
|
|
pci_write_config_dword(nb->misc, 0x1b8, reg & ~0x180000);
|
|
}
|
|
|
|
cuid = cpu_data(cpu).cpu_core_id;
|
|
mask <<= 4 * cuid;
|
|
mask |= (0xf ^ (1 << cuid)) << 26;
|
|
|
|
pci_write_config_dword(nb->link, 0x1d4, mask);
|
|
|
|
/* reset BAN mode if L3 partitioning returned to reset state */
|
|
pci_read_config_dword(nb->link, 0x1d4, ®);
|
|
if (reg == reset) {
|
|
pci_read_config_dword(nb->misc, 0x1b8, ®);
|
|
reg &= ~0x180000;
|
|
pci_write_config_dword(nb->misc, 0x1b8, reg | ban);
|
|
}
|
|
|
|
return 0;
|
|
}
|
|
|
|
static void amd_cache_gart(void)
|
|
{
|
|
u16 i;
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_GART))
|
|
return;
|
|
|
|
flush_words = kmalloc_array(amd_northbridges.num, sizeof(u32), GFP_KERNEL);
|
|
if (!flush_words) {
|
|
amd_northbridges.flags &= ~AMD_NB_GART;
|
|
pr_notice("Cannot initialize GART flush words, GART support disabled\n");
|
|
return;
|
|
}
|
|
|
|
for (i = 0; i != amd_northbridges.num; i++)
|
|
pci_read_config_dword(node_to_amd_nb(i)->misc, 0x9c, &flush_words[i]);
|
|
}
|
|
|
|
void amd_flush_garts(void)
|
|
{
|
|
int flushed, i;
|
|
unsigned long flags;
|
|
static DEFINE_SPINLOCK(gart_lock);
|
|
|
|
if (!amd_nb_has_feature(AMD_NB_GART))
|
|
return;
|
|
|
|
/*
|
|
* Avoid races between AGP and IOMMU. In theory it's not needed
|
|
* but I'm not sure if the hardware won't lose flush requests
|
|
* when another is pending. This whole thing is so expensive anyways
|
|
* that it doesn't matter to serialize more. -AK
|
|
*/
|
|
spin_lock_irqsave(&gart_lock, flags);
|
|
flushed = 0;
|
|
for (i = 0; i < amd_northbridges.num; i++) {
|
|
pci_write_config_dword(node_to_amd_nb(i)->misc, 0x9c,
|
|
flush_words[i] | 1);
|
|
flushed++;
|
|
}
|
|
for (i = 0; i < amd_northbridges.num; i++) {
|
|
u32 w;
|
|
/* Make sure the hardware actually executed the flush*/
|
|
for (;;) {
|
|
pci_read_config_dword(node_to_amd_nb(i)->misc,
|
|
0x9c, &w);
|
|
if (!(w & 1))
|
|
break;
|
|
cpu_relax();
|
|
}
|
|
}
|
|
spin_unlock_irqrestore(&gart_lock, flags);
|
|
if (!flushed)
|
|
pr_notice("nothing to flush?\n");
|
|
}
|
|
EXPORT_SYMBOL_GPL(amd_flush_garts);
|
|
|
|
static void __fix_erratum_688(void *info)
|
|
{
|
|
#define MSR_AMD64_IC_CFG 0xC0011021
|
|
|
|
msr_set_bit(MSR_AMD64_IC_CFG, 3);
|
|
msr_set_bit(MSR_AMD64_IC_CFG, 14);
|
|
}
|
|
|
|
/* Apply erratum 688 fix so machines without a BIOS fix work. */
|
|
static __init void fix_erratum_688(void)
|
|
{
|
|
struct pci_dev *F4;
|
|
u32 val;
|
|
|
|
if (boot_cpu_data.x86 != 0x14)
|
|
return;
|
|
|
|
if (!amd_northbridges.num)
|
|
return;
|
|
|
|
F4 = node_to_amd_nb(0)->link;
|
|
if (!F4)
|
|
return;
|
|
|
|
if (pci_read_config_dword(F4, 0x164, &val))
|
|
return;
|
|
|
|
if (val & BIT(2))
|
|
return;
|
|
|
|
on_each_cpu(__fix_erratum_688, NULL, 0);
|
|
|
|
pr_info("x86/cpu/AMD: CPU erratum 688 worked around\n");
|
|
}
|
|
|
|
static __init int init_amd_nbs(void)
|
|
{
|
|
amd_cache_northbridges();
|
|
amd_cache_gart();
|
|
|
|
fix_erratum_688();
|
|
|
|
return 0;
|
|
}
|
|
|
|
/* This has to go after the PCI subsystem */
|
|
fs_initcall(init_amd_nbs);
|