kernel_optimize_test/drivers/iio/temperature
Crt Mori c68a67b7ad iio: mlx96014: Replace offset sign
Changed the offset to negative as usual equation is: (raw +
offset)*scale and in this
case offset should be negative (as we deduct 273.15 Kelvin to get temperature
in Celsius).

Signed-off-by: Crt Mori <cmo@melexis.com>
Acked-by: Peter Meerwald <pmeerw@pmeerw.net>
Signed-off-by: Jonathan Cameron <jic23@kernel.org>
2015-07-19 12:23:39 +01:00
..
Kconfig iio: Add Melexis mlx90614 contact-less infrared temperature sensor driver 2014-05-03 11:38:13 +01:00
Makefile iio: Add Melexis mlx90614 contact-less infrared temperature sensor driver 2014-05-03 11:38:13 +01:00
mlx90614.c iio: mlx96014: Replace offset sign 2015-07-19 12:23:39 +01:00