ALSA: oxygen: fix analog capture on Claro halo cards
On the HT-Omega Claro halo card, the ADC data must be captured from the second I2S input. Using the default first input, which isn't connected to anything, would result in silence. Signed-off-by: Erik J. Staab <ejs@insightbb.com> Signed-off-by: Clemens Ladisch <clemens@ladisch.de> Cc: <stable@kernel.org> Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
parent
b30a3f6257
commit
0873a5ae74
|
@ -543,6 +543,10 @@ static int __devinit get_oxygen_model(struct oxygen *chip,
|
|||
chip->model.suspend = claro_suspend;
|
||||
chip->model.resume = claro_resume;
|
||||
chip->model.set_adc_params = set_ak5385_params;
|
||||
chip->model.device_config = PLAYBACK_0_TO_I2S |
|
||||
PLAYBACK_1_TO_SPDIF |
|
||||
CAPTURE_0_FROM_I2S_2 |
|
||||
CAPTURE_1_FROM_SPDIF;
|
||||
break;
|
||||
}
|
||||
if (id->driver_data == MODEL_MERIDIAN ||
|
||||
|
|