[ALSA] ice1712 - Fix wordclock status on Delta1010LT
Modules: ICE1712 driver I posted this patch to bug 1806 a while back, and have been awaiting a reply or commit. It currently reports the Locked/No Signal text backwards in envy24control, since i was using an older version of envy24control when I wrote the original code. The Locked/No Signal test was recently reversed in envy24control cvs, so the test in my code needs to be reversed as well. Here is the patch, once again. Signed-off-by: Takashi Iwai <tiwai@suse.de>
This commit is contained in:
parent
92621f130e
commit
381e3cda68
@ -412,7 +412,7 @@ int snd_ice1712_delta1010lt_wordclock_status_get(struct snd_kcontrol *kcontrol,
|
||||
if (snd_i2c_sendbytes(ice->cs8427, ®, 1) != 1)
|
||||
snd_printk(KERN_ERR "unable to send register 0x%x byte to CS8427\n", reg);
|
||||
snd_i2c_readbytes(ice->cs8427, ®, 1);
|
||||
ucontrol->value.integer.value[0] = (reg ? 0 : 1);
|
||||
ucontrol->value.integer.value[0] = (reg ? 1 : 0);
|
||||
return 0;
|
||||
}
|
||||
|
||||
|