hwmon: (pwm-fan) Check return value from devm_add_action_or_reset
devm_add_action_or_reset() can fail due to a memory allocation failure.
Check for it and return the error if that happens.
Fixes: 37bcec5d9f
("hwmon: (pwm-fan) Use devm_thermal_of_cooling_device_register")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
b9bb92e1d1
commit
5696e4aaab
|
@ -320,8 +320,10 @@ static int pwm_fan_probe(struct platform_device *pdev)
|
|||
dev_err(dev, "Failed to enable fan supply: %d\n", ret);
|
||||
return ret;
|
||||
}
|
||||
devm_add_action_or_reset(dev, pwm_fan_regulator_disable,
|
||||
ctx->reg_en);
|
||||
ret = devm_add_action_or_reset(dev, pwm_fan_regulator_disable,
|
||||
ctx->reg_en);
|
||||
if (ret)
|
||||
return ret;
|
||||
}
|
||||
|
||||
ctx->pwm_value = MAX_PWM;
|
||||
|
@ -337,7 +339,9 @@ static int pwm_fan_probe(struct platform_device *pdev)
|
|||
return ret;
|
||||
}
|
||||
timer_setup(&ctx->rpm_timer, sample_timer, 0);
|
||||
devm_add_action_or_reset(dev, pwm_fan_pwm_disable, ctx);
|
||||
ret = devm_add_action_or_reset(dev, pwm_fan_pwm_disable, ctx);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
of_property_read_u32(dev->of_node, "pulses-per-revolution", &ppr);
|
||||
ctx->pulses_per_revolution = ppr;
|
||||
|
|
Loading…
Reference in New Issue
Block a user