iio: hid-sensor-magn-3d: Fix return values
IIO_CHAN_INFO_SAMP_FREQ and IIO_CHAN_INFO_HYSTERESIS cases ignored the actual return values (which could be -EINVAL) and instead returned IIO_VAL_INT_PLUS_MICRO always. Return the actual value obtained from the functions. Both functions return IIO_VAL_INT_PLUS_MICRO upon success. Signed-off-by: Sachin Kamat <sachin.kamat@samsung.com> Cc: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
parent
2f084c1756
commit
5f25b41f7e
@ -110,7 +110,6 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
|
||||
struct magn_3d_state *magn_state = iio_priv(indio_dev);
|
||||
int report_id = -1;
|
||||
u32 address;
|
||||
int ret;
|
||||
int ret_type;
|
||||
s32 poll_value;
|
||||
|
||||
@ -153,14 +152,12 @@ static int magn_3d_read_raw(struct iio_dev *indio_dev,
|
||||
ret_type = IIO_VAL_INT;
|
||||
break;
|
||||
case IIO_CHAN_INFO_SAMP_FREQ:
|
||||
ret = hid_sensor_read_samp_freq_value(
|
||||
ret_type = hid_sensor_read_samp_freq_value(
|
||||
&magn_state->common_attributes, val, val2);
|
||||
ret_type = IIO_VAL_INT_PLUS_MICRO;
|
||||
break;
|
||||
case IIO_CHAN_INFO_HYSTERESIS:
|
||||
ret = hid_sensor_read_raw_hyst_value(
|
||||
ret_type = hid_sensor_read_raw_hyst_value(
|
||||
&magn_state->common_attributes, val, val2);
|
||||
ret_type = IIO_VAL_INT_PLUS_MICRO;
|
||||
break;
|
||||
default:
|
||||
ret_type = -EINVAL;
|
||||
|
Loading…
Reference in New Issue