bq27x00_battery: Name of cycle count property

This patch fix using correct property POWER_SUPPLY_PROP_CYCLE_COUNT
for cycle count instead POWER_SUPPLY_PROP_CHARGE_COUNTER

Signed-off-by: Pali Rohár <pali.rohar@gmail.com>
Tested-by: Pali Rohár <pali.rohar@gmail.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This commit is contained in:
Pali Rohár 2011-04-30 23:59:35 +02:00 committed by Anton Vorontsov
parent 6f9efe76cb
commit 73c244a8a5

View File

@ -4,6 +4,7 @@
* Copyright (C) 2008 Rodolfo Giometti <giometti@linux.it>
* Copyright (C) 2008 Eurotech S.p.A. <info@eurotech.it>
* Copyright (C) 2010-2011 Lars-Peter Clausen <lars@metafoo.de>
* Copyright (C) 2011 Pali Rohár <pali.rohar@gmail.com>
*
* Based on a previous work by Copyright (C) 2008 Texas Instruments, Inc.
*
@ -76,7 +77,7 @@ struct bq27x00_reg_cache {
int time_to_empty_avg;
int time_to_full;
int charge_full;
int charge_counter;
int cycle_count;
int capacity;
int flags;
@ -115,7 +116,7 @@ static enum power_supply_property bq27x00_battery_props[] = {
POWER_SUPPLY_PROP_CHARGE_FULL,
POWER_SUPPLY_PROP_CHARGE_NOW,
POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN,
POWER_SUPPLY_PROP_CHARGE_COUNTER,
POWER_SUPPLY_PROP_CYCLE_COUNT,
POWER_SUPPLY_PROP_ENERGY_NOW,
};
@ -267,7 +268,7 @@ static void bq27x00_update(struct bq27x00_device_info *di)
cache.time_to_empty_avg = bq27x00_battery_read_time(di, BQ27x00_REG_TTECP);
cache.time_to_full = bq27x00_battery_read_time(di, BQ27x00_REG_TTF);
cache.charge_full = bq27x00_battery_read_lmd(di);
cache.charge_counter = bq27x00_battery_read_cyct(di);
cache.cycle_count = bq27x00_battery_read_cyct(di);
if (!is_bq27500)
cache.current_now = bq27x00_read(di, BQ27x00_REG_AI, false);
@ -496,8 +497,8 @@ static int bq27x00_battery_get_property(struct power_supply *psy,
case POWER_SUPPLY_PROP_CHARGE_FULL_DESIGN:
ret = bq27x00_simple_value(di->charge_design_full, val);
break;
case POWER_SUPPLY_PROP_CHARGE_COUNTER:
ret = bq27x00_simple_value(di->cache.charge_counter, val);
case POWER_SUPPLY_PROP_CYCLE_COUNT:
ret = bq27x00_simple_value(di->cache.cycle_count, val);
break;
case POWER_SUPPLY_PROP_ENERGY_NOW:
ret = bq27x00_battery_energy(di, val);