hwmon/ds1621: Fix swapped temperature limits
The low temperature limit and the high temperature limit registers have been accidentally swapped, causing alarms to trigger when they shouldn't. Signed-off-by: Jean Delvare <khali@linux-fr.org> Acked-by: Aurelien Jarno <aurelien@aurel32.net>
This commit is contained in:
parent
c420bc9f09
commit
7574d7e937
@ -53,8 +53,8 @@ MODULE_PARM_DESC(polarity, "Output's polarity: 0 = active high, 1 = active low")
|
||||
|
||||
/* The DS1621 registers */
|
||||
#define DS1621_REG_TEMP 0xAA /* word, RO */
|
||||
#define DS1621_REG_TEMP_MIN 0xA1 /* word, RW */
|
||||
#define DS1621_REG_TEMP_MAX 0xA2 /* word, RW */
|
||||
#define DS1621_REG_TEMP_MIN 0xA2 /* word, RW */
|
||||
#define DS1621_REG_TEMP_MAX 0xA1 /* word, RW */
|
||||
#define DS1621_REG_CONF 0xAC /* byte, RW */
|
||||
#define DS1621_COM_START 0xEE /* no data */
|
||||
#define DS1621_COM_STOP 0x22 /* no data */
|
||||
@ -328,9 +328,9 @@ static struct ds1621_data *ds1621_update_client(struct device *dev)
|
||||
|
||||
/* reset alarms if necessary */
|
||||
new_conf = data->conf;
|
||||
if (data->temp < data->temp_min)
|
||||
if (data->temp > data->temp_min)
|
||||
new_conf &= ~DS1621_ALARM_TEMP_LOW;
|
||||
if (data->temp > data->temp_max)
|
||||
if (data->temp < data->temp_max)
|
||||
new_conf &= ~DS1621_ALARM_TEMP_HIGH;
|
||||
if (data->conf != new_conf)
|
||||
ds1621_write_value(client, DS1621_REG_CONF,
|
||||
|