[NETEM]: report reorder percent correctly.
If you setup netem to just delay packets; "tc qdisc ls" will report the reordering as 100%. Well it's a lie, reorder isn't used unless gap is set, so just set value to 0 so the output of utility is correct. Signed-off-by: Stephen Hemminger <shemminger@linux-foundation.org> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
7e58886b45
commit
a362e0a789
@ -429,7 +429,8 @@ static int netem_change(struct Qdisc *sch, struct rtattr *opt)
|
||||
/* for compatiablity with earlier versions.
|
||||
* if gap is set, need to assume 100% probablity
|
||||
*/
|
||||
q->reorder = ~0;
|
||||
if (q->gap)
|
||||
q->reorder = ~0;
|
||||
|
||||
/* Handle nested options after initial queue options.
|
||||
* Should have put all options in nested format but too late now.
|
||||
|
Loading…
Reference in New Issue
Block a user