iio: bmp280: fix compensation of humidity
Limit the output of humidity compensation to the range between 0 and 100 percent. Depending on the calibration parameters of the individual sensor it happens, that a humidity above 100 percent or below 0 percent is calculated, which don't make sense in terms of relative humidity. Add a clamp to the compensation formula as described in the datasheet of the sensor in chapter 4.2.3. Although this clamp is documented, it was never in the driver of the kernel. It depends on the circumstances (calibration parameters, temperature, humidity) if one can see a value above 100 percent without the clamp. The writer of this patch was working with this type of sensor without noting this error. So it seems to be a rare event when this bug occures. Signed-off-by: Andreas Klinger <ak@it-klinger.de> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
c12d80aeb9
commit
dee2dabc0e
|
@ -271,6 +271,8 @@ static u32 bmp280_compensate_humidity(struct bmp280_data *data,
|
|||
+ (s32)2097152) * calib->H2 + 8192) >> 14);
|
||||
var -= ((((var >> 15) * (var >> 15)) >> 7) * (s32)calib->H1) >> 4;
|
||||
|
||||
var = clamp_val(var, 0, 419430400);
|
||||
|
||||
return var >> 12;
|
||||
};
|
||||
|
||||
|
|