[POWERPC] Don't complain if size-cells == 0 in prom_parse()
An mdio bus scan was added with ucc_geth phylib migration patches, now machines complain on boot, saying: prom_parse: Bad cell count for /qe@e0100000/mdio@2120/ethernet-phy@00 prom_parse: Bad cell count for /qe@e0100000/mdio@2120/ethernet-phy@01 since size-cells can indeed be 0, this patch fixes the check. Signed-off-by: Kim Phillips <kim.phillips@freescale.com> Signed-off-by: Paul Mackerras <paulus@samba.org>
This commit is contained in:
parent
e147ec8f18
commit
fd6e9d3945
@ -24,7 +24,7 @@
|
||||
/* Max address size we deal with */
|
||||
#define OF_MAX_ADDR_CELLS 4
|
||||
#define OF_CHECK_COUNTS(na, ns) ((na) > 0 && (na) <= OF_MAX_ADDR_CELLS && \
|
||||
(ns) > 0)
|
||||
(ns) >= 0)
|
||||
|
||||
static struct of_bus *of_match_bus(struct device_node *np);
|
||||