tmp_suning_uos_patched/Documentation/networking/cxacru-cf.py
Simon Arlott 817db5b34e USB: cxacru: remove cxacru-cf.bin loader
This has never worked properly because wsize passed to
cxacru_cm() is incorrectly set to the number of values
instead of the data bytes. The maximum number of values
that can be set at once is 7 which means the device will
not get enough data to work with and none of the
configuration values will be used.

At least one existing cxacru-cf.bin file contains invalid
data which will prevent the modem from syncing properly.

Fixing it is likely to break existing systems, and the
new sysfs interface for setting configuration parameters
can provide the same functionality. A script is provided
to convert from the original format.

Signed-off-by: Simon Arlott <simon@fire.lp0.eu>
Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
2010-03-02 14:53:01 -08:00

49 lines
1.6 KiB
Python

#!/usr/bin/env python
# Copyright 2009 Simon Arlott
#
# This program is free software; you can redistribute it and/or modify it
# under the terms of the GNU General Public License as published by the Free
# Software Foundation; either version 2 of the License, or (at your option)
# any later version.
#
# This program is distributed in the hope that it will be useful, but WITHOUT
# ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or
# FITNESS FOR A PARTICULAR PURPOSE. See the GNU General Public License for
# more details.
#
# You should have received a copy of the GNU General Public License along with
# this program; if not, write to the Free Software Foundation, Inc., 59
# Temple Place - Suite 330, Boston, MA 02111-1307, USA.
#
# Usage: cxacru-cf.py < cxacru-cf.bin
# Output: values string suitable for the sysfs adsl_config attribute
#
# Warning: cxacru-cf.bin with MD5 hash cdbac2689969d5ed5d4850f117702110
# contains mis-aligned values which will stop the modem from being able
# to make a connection. If the first and last two bytes are removed then
# the values become valid, but the modulation will be forced to ANSI
# T1.413 only which may not be appropriate.
#
# The original binary format is a packed list of le32 values.
import sys
import struct
i = 0
while True:
buf = sys.stdin.read(4)
if len(buf) == 0:
break
elif len(buf) != 4:
sys.stdout.write("\n")
sys.stderr.write("Error: read {0} not 4 bytes\n".format(len(buf)))
sys.exit(1)
if i > 0:
sys.stdout.write(" ")
sys.stdout.write("{0:x}={1}".format(i, struct.unpack("<I", buf)[0]))
i += 1
sys.stdout.write("\n")