Return -EINVAL if pdata is NULL, otherwise we have NULL dereference bug.
This patch also moves the code checking pdata earlier in lp872x_probe.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch implements the .set_ramp_delay callback to set the ramp_delay on
hardware for BUCK2/3/4 if ramp_delay is set in regulator constraints.
This patch also do some cleaning work for unrequired members of
struct max77686_data.
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Fixes link failure due to devm_gpio_request_one()
Reported-by: Stephen Rothwell <sfr@canb.auug.org.au>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This driver supports TI/National LP8720, LP8725 PMIC.
Signed-off-by: Milo(Woogyom) Kim <milo.kim@ti.com>
Reviewed-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The S5M8767A can't know status of ap reset.
So, After AP watchdog reset, AP can't boot normally.
Problem can be happened like below condition.
- AP Bootable lowest voltage(vdd_arm): 0.9v
- AP DVFS voltage table: 0.8v, 0.9v, 1.0v
- During AP works on lowest voltage(0.8V), watchdog reset is asserted
- AP can't boot, because vdd arm is still 0.8v
Solution
- Basic concept:
After ap watchdog reset, GPIO configuration is changed by default value
- S5M8767A has function of voltage control with gpio (8 levels with 3 gpios)
- Set bootable voltage on level 0 -> can work with default gpio configuration
- In the probing, Change voltage control level from level 0 to level 1
- Execute normal dvfs operation on level 1
- After watchdog reset, ap gpio is set by default value
- PMIC operation mode is changed by ap reset (level1 -> level0)
- Regardless of previous vdd_arm voltage, AP always can be booted.
Signed-off-by: Sangbeom Kim <sbkim73@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch converts the driver to use regulator_set_voltage_time_sel() as
.set_voltage_time_sel() callback. It also sets ramp_delay as 100000 uV/us for
LDOs & normal BUCKs and 27500 uV/us(default/reset value) for BUCKs[2/3/4] in
regulator_desc[].
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
In current mapping table settings, min_uV/max_uV are always
equal to volt_table[0] and volt_table[table_len -1].
Thus remove min_uV and max_uV from struct tps_info.
The table based mapping with table_len == 1 means fixed voltage.
So we don't need fixed flag to differentiate if it is fixed or not.
This patch adds DCDC_FIXED_3300000_VSEL_table and DCDC_FIXED_1800000_VSEL_table
for fixed voltage cases. So we can convert tps65023_dcdc_ops to
regulator_list_voltage_table. This makes the code simpler.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
If .is_enabled callback is not implemented, regulator core assumes that the
regulator is always on. Thus we don't need mc13xxx_sw_regulator_is_enabled
function.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Due to the lack of a generic clock API we'd had the 32kHz clock in the
regulator driver but this is definitely a Linux-specific thing and now
we have a clock API hopefully the code can be moved elsewhere. Try to
avoid getting DTs deployed relying on the 32kHz clock by removing it
from the bindings, grep seems to tell me it's not currently used anyway.
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This change makes it possible to set ramp_delay with 0.xxx mV/uS without
truncation issue.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For table based mapping, we can calculate voltage difference by below equation:
abs(rdev->desc->volt_table[new_selector] - rdev->desc->volt_table[old_selector])
Thus we can make regulator_set_voltage_time_sel work for table based mapping.
regulator_set_voltage_time_sel() only supports linear or table based mapping.
In case it is misused, also warn if neither linear nor table based mapping
is used with regulator_set_voltage_time_sel().
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For some hardwares ramp_delay for BUCKs is a configurable parameter which can
be configured through DT or board file.This patch adds ramp_delay to regulator
constraints and allow user to configure it for regulators which supports this
feature, through DT or board file. It will provide two ways of setting the
ramp_delay for a regulator:
First, by setting it as constraints in board file(for configurable
regulators) and set_machine_constraints() will take care of setting it on
hardware by calling(the provided) .set_ramp_delay() operation(callback).
Second, by setting it as data in regulator_desc(as fixed/default
ramp_delay rate) for a regulator in driver.
regulator_set_voltage_time_sel() will give preference to
constraints->ramp_delay while reading ramp_delay rate for regulator. Similarly
users should also take care accordingly while refering ramp_delay rate(in case
of implementing their private .set_voltage_time_sel() callbacks for different
regulators).
[Rewrote subject for 80 columns -- broonie]
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The min_uV and max_uV are not really used in the code and misleading because
the min_uV and max_uV settings does not match the value in the voltage table.
For example, we have
static const unsigned int ldo_vaux3_voltages[] = {
1200000,
1500000,
1800000,
2100000,
2500000,
2750000,
2790000,
2910000,
};
With below min_uV/max_uV settings for AB8500_LDO_AUX3.
.min_uV = 1100000,
.max_uV = 3300000,
The min_uV/max_uV for AB8500_LDO_AUX3 seems copy-paste from AB8500_LDO_AUX2
and is wrong.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Also removes set_voltage_time_sel callback from ab8500_regulator_fixed_ops
because the voltage won't change. ( And ab8500_regulator_fixed_ops does not
implement get_voltage_sel so set_voltage_time_sel won't be called )
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
The voltage range checking should be to ensure mc13xxx_regulators[id].voltages[0]
falls with min_uV and max_uV.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For linear mappings, we can use below equation to get the voltage difference
between new_selector and old_selector:
abs(new_selector - old_selector) * rdev->desc->uV_step
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
For fixed voltage, the n_voltages should be 1 rather than 0.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Reuse map_voltage() to get the selector of a given uV.
Then we can remove wm8350_ldo_mvolts_to_val() and wm8350_dcdc_mvolts_to_val().
Also remove unused wm8350_dcdc_val_to_mvolts() function.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Call wm8350_ldo_list_voltage() instead of open code to verify selected voltage
falls within specified range.
Use wm8350_ldo_list_voltage() here is less error prone.
wm8350_ldo_val_to_mvolts() is only used in wm8350_ldo_list_voltage now, so
remove it and move the implementation to wm8350_ldo_list_voltage().
This patch also include below small changes in wm8350_ldo_map_voltage:
1. wm8350_ldo_map_voltage() returns selector, thus rename variable mV to sel.
2. Use DIV_ROUND_UP macro to calculate selector.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch converts .is_enabled and .get_voltage_sel to
regulator_is_enabled_regmap and regulator_get_voltage_sel_regmap.
For .enable, .disable, and .set_voltage_sel, the write protect level is either
1 or 2. So we cannot use regulator_[enable|disable|set_voltage_sel]_regmap.
Now we store the enable reg/mask and vsel reg/mask in regulator_desc,
so we can remove enable_mask, set_vout_reg, and set_vout_mask from
struct tps_info.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Adjust the equation for selector >= 15 for better readability.
The equation "1700000 + ((selector - 15) * 100000)" can be interpreted by:
Starting from selector 15: Steps of 100mV from 1700mV
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
To apply delay time for voltage change,
replace s5m8767_set_voltage with s5m8767_set_voltage_sel.
Signed-off-by: Sangbeom Kim <sbkim73@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Call wm8400_ldo_list_voltage() instead of open code to verify selected voltage
falls within specified range.
Use wm8400_ldo_list_voltage() here is less error prone.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
As s5m8767a is revisioned, remove unnecessary buck 2,3,4 initialization routine.
Signed-off-by: Sangbeom Kim <sbkim73@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV.
The unit of ramp_delay is mV/us.
Current code multiples 1000 at wrong place.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
rdev->desc->uV_step * abs(new_selector - old_selector) returns uV.
The unit of ramp_rate is mV/us.
Thus 1000 should be multiplied.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Reviewed-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This patch adds regulator_set_voltage_time_sel(), to move into core, the
commonly used code by drivers to provide the .set_voltage_time_sel callback.
It will also allow us to configure different ramp delay for different
regulators easily.
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
If this driver only works when pdata->num_regulators == MAX77686_REGULATORS,
let's check it earlier.
Also remove unused num_regulators from struct max77686_data.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
isl_fixed_ops does not implement set_voltage_sel callback, adding map_voltage
here is misleading.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Also adds tps6586x_ldo0_voltages mapping table for LDO0, so we can remove the
hack in tps6586x_list_voltage() and convert it to regulator_list_voltage_table.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
It's a little bit hard to read that the "else" case means id == PALMAS_REG_SMPS10.
if (id != PALMAS_REG_SMPS10){
do something for the cases id != PALMAS_REG_SMPS10;
} else {
do something for the case id == PALMAS_REG_SMPS10;
}
This patch changes above syntax to switch statement.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
Current code actually clears more bits than PALMAS_SMPS12_CTRL_MODE_ACTIVE_MASK bits.
Signed-off-by: Axel Lin <axel.lin@gmail.com>
Acked-by: Graeme Gregory <gg@slimlogic.co.uk>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>